<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-15 17-23-39
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 74 kHz 14723 23,2222
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,60 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 74 kHz MIN: 9 kHz % above 76 kHz: 23,2222 Acquired: 2026.09.15 17.22.36 Total samples: 14723 Equivalent time: 0:12:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,4 dBr MIN: 4,6 dBr AVE: 5,60 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2026.09.15 17.22.35) 17.08 17.10 17.12 17.14 17.16 17.18 17.20 17.22 0 2 4 6 Pm [dBr]